The 2019 WEFTEC Technical Exhibition and Conference was held September 23-25 at McCormick Place in Chicago. The event featured 148 technical sessions, 27 workshops, 16 mobile sessions, seven local facility tours and 1,000+ exhibitors.  Both Blower & Vacuum Best Practices and Compressed Air Best Practices® Magazines were pleased to be in the literature bins at the 2019 WEFTEC!

Aeration Blowers

Sizing, selection, and adjusting control valves often causes confusion for process and control system designers. Improper valve application can cause operating problems for plant staff and waste blower power. Basing the airflow control system design on fundamental principles will improve valve and control system performance.

Industrial Blowers

Blower systems designed to deliver continuous airflow at pressures of 50 psig or below are critical to the operation of many processes including wastewater treatment, pneumatic conveying, fluid catalytic cracking, and fermentation to name a few. Many circumstances could arise that require an operator to require a rental blower for a period.

Rough Vac

Many heat-treating applications put difficult demands on vacuum pumps in general and oil-sealed pumps, in particular. Byproducts from the heat-treating process can contaminate the vacuum pump oil and create higher vapor pressures that cause deteriorated vacuum levels in the heat-treating chamber, or buildup and blockages in the pump mechanism.

Medium/High Vac

Distillation, degassing, drying, filtration, membrane separation, adsorption, and crystallization are all among the separation processes that rely on the differences in the physical properties of substances in a mixture. Distillation relies on the differences in boiling point or in vapor pressure versus temperature characteristics. Heating, evaporation, and condensing are the tools used in distillation that separate the liquid constituents in a liquid mixture.

Measurement

Every municipality and utility is facing the reality of rising energy costs. In 2010, the Town of Billerica, MA, which is located 22 miles northwest of Boston with a population of just under 40,000 residents, engaged Process Energy Services and Woodard & Curran to conduct an energy evaluation of the Town’s Wastewater Treatment Facility (WWTF) and pump station systems sponsored by National Grid. The objective of the evaluation was to provide an overview of each facility system to determine how electrical energy and natural gas were being used at the facility and to identify and develop potential costsaving projects.

Purification

Contamination such as humidity, oxygen or microbiological ingress can impact drug stability throughout the product life cycle. To prevent the risks of stability failure of highly moisture sensitive drugs (e.g. dry powder for inhalation), or the risk of biological ingress of parenteral drugs, highly sensitive integrity tests are required. Most test methods are very challenging in regards to time, effort, complexity or the limitation of sensitivity and detection range.

Vac Generation

Using suction cups and air-driven vacuum pumps is a preferable gripping and handling method of corrugated cardboard materials and boxes in carton-machines like case/carton erectors and rotary cartoners. Robot based applications, like palletizing and de-palletizing, are other examples where the best practice technology for gripping and handling is by suction cups and air-driven vacuum pumps.  
A leading soft drink bottling manufacturer’s compressed air needs were threatening to exceed its Michigan plant’s compressed air capacity. Faced with the cost of buying a new compressor, the soft drink bottling manufacturer re-assessed their compressed air use to identify compressor and energy savings opportunities. In the audit, the soft drink bottling manufacturer identified the use of compressed air in a gap transfer as a source of compressed air and energy inefficiency.
This article will examine in detail four of the five acceptable WAGD implementations under NFPA 99, along with some alternative ways they may be implemented. This article will not deal with passive implementations.
The roots of our company start with my father, Jan Dekker, who was heavily involved with oil-sealed liquid ring vacuum systems used in the gold mines of South Africa. This was in the mid-1970’s when gold prices were going up. Vacuum systems (in the mines) were optimized by improving vacuum levels using oil instead of water and by adding vacuum boosters.
There is an enormous population of vacuum generators being used successfully by industry. Applications range from pick & place to vapor extraction to bulk material handling and the number of installations is growing. Before proceeding with an installation utilizing these devices, there are two general issues to consider: efficiency and appropriateness.
Swiss brush company Ebnat-Kappel uses non contact transfer technology from Bosch Rexroth to automate a problematic section of its packaging production process.
A compressed air system assessment saved this building materials manufacturer over $518,000 per year in energy costs, with a simple ROI of 11 months. 
Blower & Vacuum Best Practices interviewed Mr. Sid Van der Meer and Mr. Terry Nickel from Northwest Equipment Ltd in Airdrie, Canada.
It’s no secret that cost-cutting is now a main focus for many business owners. When times get tough, the first reaction is figure out where it’s possible to spend less in order to maintain the bottom line. Over the last year, there have been countless examples of companies that eliminated programs, slashed entire departments, and sliced into salaries to protect profits.
The snack food facility is running with two normally separated compressed air production systems: the main plant system and the nitrogen system.
Most printing facilities use vacuum for one process or another.  I recently spoke with Jesse Krivolavek, (a vacuum system efficiency specialist with IVS, Inc.) about his recent adventures in the world of printing.